Calibration Wizard

The calibration wizard can be used for calibration using existing files as well as by capturing data in place. The following data is required for offline calibration :

Calibration Data Required
Lens Checkerboard images
Common Phase VXL of a camera pointing to a flat wall
Per Pixel Offset VXL of a camera pointing to a flat wall
Non Linearity CSV file containing measured distance and phase values at the center pixel
Temperature CSV file containing temperatures vs phase values, in a temperature chamber

Data for lens, common phase and pixelwise phase offset calibration can be captured live, using a depth camera. For all other calibrations, it is advised to use existing data captured using voxel viewer.

Starting the wizard

The wizard can be started by running the CalibrationWizard.py file. The first page that comes up is the following:

images/firstpage.PNG

Here, you can select which calibrations are required to be performed. Also, if you already have captured data, you can select the “Select files from PC” parameter. Otherwise, choose “Capture from Camera.”

Capture From Camera

Once you select a camera, you’ll be asked to select a new profile or edit an existing profile present in the camera. If you create a new profile, you need to select a parent. Else, if you’re editing an existing profile, the conf file of that profile is changed.

images/selectDepthcamera.PNG
Once you select a depth camera connected to the device, you’re asked if you want to create a new profile or edit an existing one.
  • Create a new profile: This option will ask for a profile name as well as a profile to inherit from. Select the profile you want to inherit from and continue with the calibration.
  • Edit an existing profile: if you select a profile which is already present from the dropdown menu, the existing profile will get edited. This should NOT be used for the profiles present in the hardware (the profiles present in the hardware will have (HW) written in the end).

Select Files From PC

If you choose to select files from PC, you need to provide the information for the chipset being used. The wizard currently supports the use of TintinCDKCamera and CalculusCDKCamera chipsets. To know the camera chipset, open Voxel Viewer and look for the camera name. It can be seen in the following image:

images/cameraName.PNG

Apart from the camera name, you need to provide the conf file which was used for capturing the data. You have the option to edit this file or create a new profile, whose parent will be the conf file you pick.

  • Selecting an existing conf file will result in overwriting of the calibration parameters for the given profile.
  • Creating a new profile and selecting a parent will result in the creation of a new profile. All the missing calibrations in the selected profile will be obtained from the parent profile.

Note

  • Offline calibration requires you to change the id of the profile you’ve created. Currently, an id of 150 is being used. You need to open the conf file and change the id manually for the profile to work with the camera.
  • Offline calibration does not add the new profile to the main configuration file of a chipset. To do so, go to the conf directory, open the main configuration chipset (TintinCDKCamera.conf in case of Tintin and CalculusCDKCamera.conf in case of Calculus) and add the profile name to the main conf file.
images/selectConfFile.PNG

Selecting the strategy for calibration

The second page of the wizard asks for the specific strategy with which you wan to do a particular calibration. The different types of calibrations are as follows:

Strategy Calibration(s)
FlatWall Common Phase Offset, PixelWise Phase Offset, HDR common phase offset
Checkerboard Lens Calibration
Piecewise Non Linearity Calibration
Temperature Temperature Calibration
images/SelectMethodForCalibration.PNG

Lens Calibration

Lens calibration aims at overcoming optical distortions introduced by the lens. In absence of any optical distortions, each pixel (u_i,v_i ) can be converted to the equivalent world coordinates (x_i,y_i,z_i ) by applying the pin-hole camera model shown in Figure 18. The goal of lens calibration is to transform the distorted pixel coordinates to an equivalent coordinates that can be used under the pin-hole camera model.

images/pinhole.png

The process extracts a set of parameters commonly known as intrinsics that include nine values [k1, k2, k3, pi, p2], where [k1,k2 k3] are the radial distortion coefficients, [p1,p2 ] are the tangential distortion coefficients, and [cx,cy ] are the coordinates of the image center, and [fx,fy ] are the x and y focal distances.

The procedure takes several amplitude images of a checkerboard pattern, similar to the one shown in the figure below. The checkerboard corners are extracted as data points used in computing the intrinsics through least-square minimization. Users wishing to learn about the theory behind lens calibration are encouraged to review the OpenCV tutorial link in the Reference section.

Data Required

-Checkerboard images at various orientations. Images (or vxls) with the checkerboard should be present in the directory. The default path is /path/to/.Voxel/profiles. It is advised to keep the files under the chipset same in the camera id folder. See the image below for reference.

images/directory.PNG

-Number of rows in the checkerboard -Number of columns in the checkerboard

Calibration using a camera

When a chipset is used for calibration, it uses the /path/to/.Voxel/profiles/CameraType/cameraid folder as default. If there are existing images in the folder, those can be used. Further images can be added using the ‘Add’ icon (Refer to the image).

images/checkerBoardLive.PNG

Calibration Using Existing Data

If existing data is available, calibration can be done using the files available. You need to provide the directory containing the images/vxls along with the rows and columns in the checkerboard. There is an option to view the checkerboard corners and discard images where the algorithm isn’t able to find the corners. This will directly delete the file from the system.

Non-Linearity Calibration

For best accuracy, the relatively small nonlinear relationship that exists between the raw phase measurement and actual depth must be taken into consideration. Such relationship requires taking small steps between the starting position, and the end position, such that the travel spans the full \(2\pi\) phase interval (The \(2\pi\) interval corresponds to the distance which is equal to around 300/(2*modulation frequency), and data is required for the desired modulation frequency). The wizard can take in calibration data in *.csv format collected at calibrated optical center (cx,cy), in the following form:

<Actual Distance>, <Phase1>, < Phase2>

Here, <Actual Distance> is the actual distance, <Phase1> is the phase measured at the first modulation frequency, and <Phase2> is phase measured at second modulation frequency. These two modulation frequencies work together in the de-aliasing operation. If there is no de-aliasing operation, just <Actual Distance> and <Phase1> parameters are required.

An example file can be seen at NonLinearityExample <https://example.com>_.

The following image shows how the non linearity page looks like:

images/nonLinearityPage.png

Data Capture

To capture data, put the camera on a rail that is parallel to a flat wall. Measure the distance of the camera from the wall. At fixed distances, note the value of the phase for both modulation frequencies. For taking data for individual modulation frequencies, set the ind_freq_data_en parameter to 1. For modulation frequency 1, set ind_freq_data_sel parameter to 0 and capture data. For the second modulation frequency, set the ind_freq_data_sel parameter to 1. If just one modulation frequency is being used, just record the data for the first modulation frequency.

Calibration

In the wizard, both in live capture as well as using existing files, the calibration for non linearity is identical. You need to upload a CSV file containing the measured distance v/s phase. Data can be entered in place as well, and the wizard will save the CSV file.

Temperature Calibration

The goal of temperature calibration is to derive a set of curve-fitting coefficients used in compensating phase drift due to temperature. Normally temperature calibration only needs to be done once per design. A thermal chamber is required to collect temperature-vs-phase data into a *.csv file format. Then the *.csv file is imported into the wizard in this step to compute the compensation coefficients. Each row of the *.csv file must contain three numbers separated by comma, with the following meaning:

<Tsensor>, <Tillum>, <Measured Phase>

<Tsensor> is the imaging sensor’s temperature; <Tillum> is the temperature of the illumination driver, both in °C. Typically the data is collected in about 1°C interval. Once the *.csv file is imported, click Calibrate, and the computed temperature coefficients will be displayed at the bottom of the window, as is shown in the figure.

images/temperaturePage.png

An example file can be seen at TemperatureExample <https://example.com>_.

Common Phase Offset Calibration

Common phase calibration assumes the phase-to-depth relationship is linearized by other calibration by the time it runs. The conversion of phase to depth can then be summarized by the linear equation
\[d_{i}= \frac {c*(φ_i-φ_0i)}{2fη}+d_{0i}\]

The common phase calibration correlates measured phase with actual depth at a single point (φ_0i,d_0i ). This is done for all pixels indexed by i. Only the center pixel is correlated, and the average of 200 samples (default) is used.

images/commonPhase.png

Data Required

  • VXL files of a flat wall (the camera must be approximately parallel to the wall)
  • Modulation Frequency(ies)
  • Distance of the camera from the wall

Calibration using existing data

Data Capture - to be done previously
  • Point the camera to a flat wall and capture data. The camera should be almost parallel to the wall.
  • You need to take care to record existing data. For common phase offsets, ensure that the phase_corr1 and phase_corr2 values are set to zero. In case of TintinCDKCamera, ensure that hdr_phase_corr1 and hdr_phase_corr2 parameters are also 0. The wizard will give unexpected results if this is not ensured.
  • For dealias enabled (dealias_en = 1), record data using ind_freq_data_en parameter as 1. For the first modulation frequency, set the ind_freq_data_sel parameter to 0 and for using the second modulation frequency, set the ind_freq_data_sel parameter to 1.
  • Distance at which the VXL is captured is required. Ensure that you measure the distance of the camera from the flat wall.
  • Along with the distance, note down the modulation frequency values as well.

Calibration using existing files

  • If the dealias_en parameter is set to 1, click on the checkbox beside dealias_en. In case of CalculusCDKCamera, ignore this parameter.
  • Choose the file path for the VXL consisting of modulation frequency data. Also choose the modulation frequency and distance (do it for both the files if the dealias_en parameter is on)
  • Click on calibrate. If the data is recorded correctly, the wizard will show the values of phase_corr1 and phase_corr2. In case of an error, the program will give an error and you need to use different VXL files.

The page for existing files can be seen from the following image:

images/commonPhaseOffline.png

Calibration Using a camera

When a camera is directly used for calibration, the wizard asks for the permission to record the vxls by itself. The vxl(s) are located in the /path/to/profiles/<Camera_Name>/<Camera_id>/ folder. When dealias_en is 1, the wizard asks the user to click capture again before recording the vxl for the second modulation frequency.

Then, if the recordings are good, click on calibrate to get the coefficients. If Per pixel calibration is required, it will be calibrated using the same vxl captured for per pixel offsets.

Note

  • Ensure that lens calibration is done before Common Phase Offset Calibration. Otherwise, the offset may be incorrect and there will be an error in the computed distance.

The live capture of the common phase offset can be seen in the following image:

images/commonPhaseLive.png

PixelWise Phase Offset Calibration

For high-precision applications, pixel-to-pixel calibration is recommended. This calibration step attempts to overcome the finer pixel-to-pixel variation. Since the variation is compensated for each pixel, this calibration requires a larger storage space on the EEPROM; and only one copy of the pixel variation map can be stored.

Data Required

  • VXL file of the camera pointing to a flat wall.

Note

  • Ensure that the lens (required) and non linearity calibration (if needed) is done before the pixelwise phase offset calibration

Calibration

For both live capture and calibration using a camera, the data required is just a VXL file. Record data (in case of capture) or give the file path (in case of existing data) and hit on calibrate.

For offline capture, the page looks as follows:

images/perPixel.png

And for online data capture, the page looks as follows:

images/perPixelLive.png

Note

If common phase offset calibration is selected along with pixelwise phase offset calibration, there is no need to specify the file path. The code will use the file for common phase offset correction for calibrating the pixelwise offsets.